AMIS Analog Networking
585-300-512 Issue 7
May 1999
Intuity System AMIS Administration
5-32AMIS Remote Machine Administration
5
Enter the Address Ranges for the Remote
Machine
The Address Range section of the Machine Profile screen allows you to set prefix
and address ranges for the remote AMIS machines. Intuity AUDIX Voice
Messaging uses the prefix and address ranges to determine the remote machine
on which a remote subscriber resides when messages are addressed to that
subscriber. Refer to Chapter 2, "Planning and Design", and use the address
range plan designed on the remote machine worksheets. Refer to the following
guidelines as you administer the address ranges:
In addition to the address ranges that specify the digits
subscribers
must
enter, the local system also requires an address range that uniquely
identifies the hunt group number, or
callback number
, of the remote voice
mail system.
If the remote machine has a different country code, the address range
must contain the country code, area/trunk code, and hunt group.
If the remote machine has a different area or trunk code, only the
area/trunk code and hunt group are needed. The country code should be
omitted.
If the remote system is local, only the hunt group number should appear
for that machine.
If the remote machine can be accessed through a private network, the
network-access code and hunt group for the remote machine should
appear in the address prefix list instead.
Enter the numbers that define the mailbox extensions that can be used on the
remote system or the specific remote telephone numbers you want local
subscribers to access in the Start Ext. and End Ext. fields. Valid entries can be
from 3 to 10 digits. The length of the start and end extensions must agree with the
number shown in the Extension Length field. Leading zeros may be needed to
conform to this requirement. The end extension must be equal to or greater than
the start extension. If you specify the same number as the starting and ending
extension, a unique machine or telephone number is specified, usually to identify
the hunt group number of a remote machine.
Up to ten different ranges can be specified. AMIS address ranges and message
delivery address ranges must be unique; they cannot overlap with other AMIS
analog networking and/or message delivery address ranges. See Chapter 2,
"Planning and Design", for details.
NOTE:
The Warnings field indicates when a duplicate or overlapping range is
being assigned. If you get a warning message, display the List
Address-ranges screen to check which extension numbers are in use, then
refer to Chapter 2, "Planning and Design", to select appropriate ranges.