Equinox Systems MEGAPLEX Bedienungsanleitung Seite 58

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 238
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 57
AMIS Analog Networking
585-300-512 Issue 7
May 1999
AUDIX Administration
3-6Implementation
3
q. Log Connect Events (y/n)?
This field was added in R1V7 7:2 software for digital networking.
This field does not apply to AMIS analog networking or message
delivery, but it may be set to “y” on the local machine if digital
networking is implemented.
r. Send to non-administered recipients (y/n)?
This field was moved to this form in R1V7; in AUDIX R1V6 software,
it is on the
system:appearance
form. This field does not apply to
AMIS analog networking or message delivery on the local machine
profile; it applies only to digital networking (if implemented on the
local machine).
5. If you have changed any data in the fields, press or (F1).
6. Press to exit the form.
Task 2: Administer AMIS Loopback Test
Mailbox (Optional)
This task is optional for AMIS analog networking and does not apply to message
delivery. The loopback test mailbox is used to test the AMIS Analog Networking
feature. Any message delivered to this mailbox causes a reply to be sent to the
sending mailbox.
If remote users send an AMIS message to this mailbox, the local system sends a
copy of the message to the
incoming
mailbox of the remote user to indicate the
message was received. The local loopback mailbox keeps a copy of the
message header in its
outgoing
mailbox.
To administer a loopback test mailbox:
1. Type
su l
on the path line to access the subscriber:local form. Press
.
2. Tab to the name field and type an appropriate name (such as
loopback
).
3. Tab to the ext field and type a valid extension for a local mailbox ID.
4. Verify the service options are correct (for example, check the community
id field). Refer to the appropriate forms reference manual for details on this
form if necessary.
5. Press (F2).
6. Press to exit the form.
CHANGE RUN
Ctrl-z
RETURN
ADD
Ctrl-z
Seitenansicht 57